AI data centers require reliable cooling, power distribution, and equipment monitoring. As GPU computing density increases, supporting systems must handle higher thermal loads and more complex electrical connections.
Flexible cables for AIDC data centers connect coolant distribution units (CDUs), pumps, sensors, UPS systems, control cabinets, and monitoring devices. They support power delivery, signal transmission, and easier equipment installation.
According to ASHRAE's AI Data Center Energy and Thermal Efficiency guidance, liquid cooling and intelligent infrastructure are increasingly important for high-density AI facilities.
This guide explains the main cable applications, suitable cable types, and key selection factors for AIDC equipment manufacturers.
Table of Contents
Liquid cooling systems use pumps, heat exchangers, valves, and sensors to regulate equipment temperature.
A typical CDU requires cables for motor power, valve control, temperature measurement, pressure monitoring, and communication.
Flexible power cables connect cooling pumps and auxiliary electrical equipment. Shielded control cables transmit signals between PLCs, actuators, and controllers.
For manufacturers building compact CDU systems, suitable industrial automation cables can simplify internal equipment wiring.
The U.S. Department of Energy's data center cooling guidance also highlights the importance of cooling design and efficient facility operation.
Temperature, pressure, and flow sensors provide operating data to the cooling controller.
Shielded instrumentation and sensor cables can reduce interference affecting sensitive signals.
For example, RVVP-type shielded cables with configurations such as 2 × 0.75 mm² or 4 × 1.0 mm² may suit certain low-voltage control circuits. Final specifications depend on the connected equipment.
Where abrasion or chemical exposure is a concern, properly selected PUR flexible cables may offer additional mechanical protection.
AI data centers rely on stable electrical infrastructure.
UPS units, PDUs, and distribution cabinets require internal power connections, control circuits, and monitoring interfaces.
Flexible power cables support electrical connections in pumps, auxiliary equipment, and distribution assemblies.
Control cables connect relays, monitoring modules, and automation devices. PVC flexible cables may suit appropriate indoor equipment wiring applications.
Conductor sizing must follow current, voltage, installation temperature, and equipment requirements.
The IEC 60228:2023 conductor standard provides technical requirements for conductor cross-sections and resistance.
Cable fire performance is particularly important in enclosed electrical spaces.
Manufacturers should verify flame propagation performance, insulation rating, and applicable local regulations.
The IEC 60332-1-2:2025 standard describes a vertical flame propagation test for individual wires and cables.
Where required, equipment manufacturers can evaluate suitable flame-retardant cable solutions.
AIDC facilities use sensors, automation controllers, and communication networks to monitor operating conditions.
Electrical switching equipment and motor drives can introduce electromagnetic interference (EMI).
Shielded cables help protect low-level signals from electromagnetic disturbances.
Typical applications include temperature monitoring, pressure measurement, cooling valve control, and power equipment status signals.
Copper braid, aluminum foil, and twisted-pair structures provide different shielding characteristics.
RONA's flexible signal cable selection guide explains common shielded cable constructions, including LiYCY and twisted-pair options.
Industrial Ethernet cables may connect CDU controllers, PLCs, and equipment management systems.
Shielded Cat6A cables can support suitable Ethernet connections where proper grounding, compatible connectors, and channel specifications are maintained.
Cat8 is generally relevant to specific short-distance, high-speed applications rather than being a default requirement for infrastructure monitoring.
Reliable data center operation also depends on appropriate system design and monitoring, as outlined in the ASHRAE AI Data Center Energy Performance Framework.
Cable Type | Typical Application | Main Requirement |
|---|---|---|
Shielded Control Cable | CDU, PLC, valves | EMI protection |
Flexible Power Cable | Pumps, UPS, PDU | Electrical capacity |
Instrumentation Cable | Temperature and pressure sensors | Signal stability |
Sensor Cable | Flow and environmental monitoring | Interface compatibility |
Industrial Ethernet Cable | Equipment management networks | Transmission performance |
High-Flex Cable | Moving equipment connections | Repeated bending resistance |
Actual cable selection depends on equipment requirements. Fixed-installation flexible cables should not be confused with cables designed for continuous movement.
Determine conductor size, core count, rated voltage, current, and signal type.
Power circuits require sufficient current-carrying capacity. Sensitive instrumentation circuits may require twisted pairs and additional shielding.
PVC is commonly used for general equipment wiring. PUR may be preferable where additional abrasion or oil resistance is needed.
For applications involving repeated movement, use cables designed and tested for dynamic bending.
Review flame propagation requirements, smoke performance, cable routing, and installation conditions.
The selected product must meet applicable project standards. The ASHRAE data center standards and resources provide additional infrastructure design references.
Equipment manufacturers may require specific conductor configurations, shielding, jacket materials, colors, or finished lengths.
Early cable specification helps simplify equipment integration and reduce assembly issues.
At RONA Cable, we manufacture industrial flexible cables for machinery, electrical equipment, and automation applications.
Our product range includes flexible power cables, industrial control cables, and specialized constructions designed for different mechanical and environmental conditions.
We support OEM manufacturers seeking suitable cables for CDU assemblies, power distribution equipment, and monitoring systems.
For AIDC applications, our team can evaluate cable structure, conductor size, shielding, jacket materials, and installation requirements.
Explore our cable engineering and manufacturing capabilities to learn more about cable development and customization.
Common types include flexible power cables, shielded control cables, instrumentation cables, sensor cables, and industrial Ethernet cables.
CDUs may use flexible power cables for pumps, control cables for valves, and shielded instrumentation cables for monitoring sensors.
They help reduce electromagnetic interference affecting control and monitoring signals, particularly near power converters and motor drives.
RONA provides industrial cable manufacturing and customization services. Equipment manufacturers can submit application requirements for technical evaluation.