MREFF 3*50mm² + 1G*25mm²
RONA
85444929
500m
| Availability: | |
|---|---|
A submersible pump rubber cable is a power cable that supplies a submersible pump — including an electrical submersible pump (ESP) — working immersed in liquid. Rona-MREFF is built with compressed bare copper conductors, EPR insulation, neoprene inner and outer sheaths, and a Kevlar woven reinforcement layer. It is rated 3.6/6 kV, with a maximum conductor temperature of 90°C. Also called an oil-submerged pump cable in oilfield use. The cable is supplied flat or round to customer requirements, as an assembly of three phase conductors plus one grounding conductor.
Submersible pumps need power where the pump itself works — under liquid. The cable runs with the pump, so it must carry medium-voltage power, resist water, ozone and ultraviolet light, and survive pulling, abrasion and bending during installation and retrieval.
Rona-MREFF is designed for that duty. The three phase conductors and one grounding conductor are laid in a flat or round assembly to customer requirements; the flat form suits the narrow space alongside a pump and tubing. EPR insulation gives the 3.6/6 kV rating and a 90°C continuous conductor temperature. Neoprene inner and outer sheaths protect the cores, and a Kevlar woven reinforcement layer adds tensile strength and mechanical protection.
This is a cable for the pump power supply. It does not include the pump, motor, seals or downhole connectors. Sizes, lengths and terminations other than specified in the source file and must be confirmed before ordering.
Rated 3.6/6 kV.
Medium-voltage ESP / submersible pump power supply: rated U0/U 3.6/6 kV, test voltage AC 10.8 kV for 5 minutes.
90°C, −35°C.
90°C maximum continuous conductor temperature; lowest outdoor working temperature −35°C.
EPR insulation
EPR (ethylene-propylene rubber) insulation, nominal thickness 2.7–3.2 mm, with a semiconducting band conductor screen.
Neoprene sheaths
Neoprene (CR) inner sheath (nominal 2.0 mm) and outer sheath (nominal 3.5 mm), both black.
Kevlar reinforcement.
Kevlar woven reinforcement layer for mechanical protection and tensile strength. Kevlar is DuPont's aramid brand; Yu confirmed the reinforcement is Kevlar.
Rubber cable.
Wear, ozone, UV and humidity resistant, with certain hydrolysis resistance.
Flat or round, to order.
Flat or round 3 + 1 assembly: 3 phase conductors + 1 grounding conductor, for installation alongside the pump.
Bending radius 5D
Minimum bending radius 5D.
Construction
No. | Layer | Material / detail |
1 | Conductor | Compressed bare copper wires or tinned copper,based on customer request. |
2 | Conductor — grounding | Compressed bare copper wires or tinned copper,based on customer request. |
3 | Insulation | EPR |
4 | Inner sheath | Neoprene (CR), black |
5 | Reinforcement layer | Kevlar woven reinforcement layer; Kevlar twisted yarn approx. |
6 | Outer sheath | Neoprene (CR), black |
Applications
Submersible / ESP pumps.
Electrical submersible pumps (ESP) and submersible pumps, where a flat or round medium-voltage rubber cable runs with the pump.
Immersed pump power.
Pump power supply in immersed service, within the 90°C / −35°C temperature range and the 5D bending radius.
FAQ
Q1: What is a submersible pump rubber cable?
— It is a power cable that supplies a submersible pump, including an electrical submersible pump (ESP), working immersed in liquid. RONA Rona-MREFF has compressed copper conductors, EPR insulation, neoprene sheaths and a Kevlar woven reinforcement layer, rated 3.6/6 kV.
Q2: What is the difference between a submersible pump cable and an ESP cable?
— An ESP cable is a type of submersible pump cable: ESP means electrical submersible pump, the pump used in oil production wells. The term submersible pump cable is wider and also covers water-well pumps. This page uses submersible pump cable as the main term and ESP cable as a secondary term. In oilfield use it is also called a submersible oil pump cable or an oil-submerged pump cable.
Q3: What voltage is Rona-MREFF rated for?
— 3.6/6 kV (U0/U), with a test voltage of AC 10.8 kV for 5 minutes.
Q4: What temperatures can it work at?
— The maximum continuous conductor temperature is 90°C and the lowest outdoor working temperature is −40°C.
Q5: Can this cable be used underwater for a long time?
— Yes, within the limit stated in the specification: if used underwater for an extended period, the service life will be more than 3 years for this neoprene-sheathed construction.
Q6: What is the minimum bending radius?
— 5D — five times the cable diameter (D).
Q7: What is the MOQ and lead time?
— MOQ 500 m depending on the model; lead time 20–30 days.