LiYY, LiYCY, LiYCY-TP, and Li2YCY-PiMF cables differ primarily in conductor arrangement, insulation material, and shielding construction. LiYY is commonly used for low-interference control wiring, LiYCY adds overall copper braid shielding, LiYCY-TP combines twisted pairs with overall shielding, and Li2YCY-PiMF provides individually shielded pairs with an additional overall shield.

The appropriate cable depends on the signals being transmitted, the electrical interference present, the wiring distance, and whether the cable remains stationary or moves during operation.

For equipment manufacturers and industrial buyers, matching these requirements is more important than choosing a cable based on its model designation alone.

Why the Same Machine May Need Different Signal Cables

Consider three electrical connections within an industrial machine.

The first connects a pushbutton inside a control cabinet. The second carries encoder signals from the opposite end of the machine. The third connects a sensor mounted on an axis that repeatedly moves through a cable carrier.

All three connections may be described as flexible signal cables, but their operating requirements are different.

The pushbutton connection mainly requires convenient installation and suitable conductor sizing. The encoder connection must maintain reliable signal transmission over its route. The moving sensor cable must also withstand repeated mechanical bending.

Before comparing cable models, two questions are particularly useful:

1、What type of signal does the cable transmit?

2、What other electrical cables and equipment are located along its routing path?

The answers help determine whether an unshielded multicore cable, an overall-shielded cable, a twisted-pair construction, or individually shielded pairs should be evaluated.

LiYY vs LiYCY: When Is Overall Shielding Necessary?

LiYY and LiYCY are common flexible signal cable constructions used in industrial equipment.

The main structural difference is the shielding.

LiYY for Low-Interference Control Wiring

LiYY typically features PVC-insulated conductors, a multicore construction, and a PVC outer sheath without additional metallic shielding.

It can be suitable for connections such as:

  • Pushbuttons inside control cabinets

  • Limit switches

  • Relay contacts

  • Short-distance discrete control circuits

  • General equipment wiring with low interference exposure

For example, when a pushbutton cable remains inside a cabinet and can be routed separately from motor power circuits, an unshielded LiYY construction may be sufficient.

However, the cable must still meet the electrical and installation requirements of the connected equipment.

LiYCY for Control Circuits Exposed to Electrical Noise

LiYCY typically adds an overall copper braided shield around the conductor assembly.

This shield helps reduce the coupling of external electromagnetic interference into the signal conductors.

It may be considered for:

  • Machine control connections

  • Instrumentation signals

  • Longer control wiring runs

  • Equipment wiring near electrical interference sources

  • Industrial control circuits requiring overall shielding

Suppose a limit switch is installed at the far end of a production machine, with its signal cable routed near motor drives or power wiring.

In this situation, LiYCY may offer an appropriate shielding option.

However, the shielding itself cannot compensate for every installation problem.

Equipment designers should evaluate cable separation, grounding, and shield termination together. The Industrial Automation Wiring and Grounding Guidelines published by Rockwell Automation provide additional guidance on industrial wiring practices and electromagnetic interference.

Why LiYCY-TP Uses Twisted Pairs

LiYCY-TP combines twisted conductor pairs with an overall copper braided shield.

The twisted-pair arrangement helps keep the conductors belonging to the same signal circuit together, which is particularly useful for balanced differential signals.

Overall shielding primarily addresses interference entering from outside the cable, while twisting can help reduce noise pickup and coupling between circuits.

Encoder Feedback Connections

Consider an encoder with differential output channels A+/A− and B+/B−.

For this application, each differential signal should use its own twisted pair:

Encoder Signal

Recommended Pair Arrangement

A+ / A−

Twisted Pair 1

B+ / B−

Twisted Pair 2

Additional differential channels

Separate pairs according to device requirements

Power supply conductors

As specified by the encoder manufacturer

A common wiring mistake is to select individual conductors from different pairs simply because their colors or terminal positions are convenient.

Although electrical continuity may be established, separating the conductors of a differential circuit defeats the intended pair arrangement.

When specifying an encoder cable, the purchase specification should identify the required number of pairs, the purpose of each pair, and any additional power conductors.

Analog Sensors and RS-485 Communication

LiYCY-TP may also be considered for multiple analog channels, sensors, and differential communication connections.

However, the designation alone does not guarantee compatibility with a particular communication protocol.

For RS-485 applications, factors such as characteristic impedance, capacitance, cable length, transmission rate, and termination must be considered.

The RS-485 Cable Specification Guide from Analog Devices explains why cable impedance, twisted-pair arrangement, and termination affect communication reliability.

When Is Li2YCY-PiMF Worth Considering?

Li2YCY-PiMF is associated with cable constructions using PE insulation, individually foil-shielded pairs, and an additional overall copper braided shield.

PiMF stands for Pairs in Metal Foil.

This construction may be useful when several sensitive signal circuits share one cable and interference between individual pairs must be controlled.

Individual Pair Shielding vs Overall Shielding

The two shielding arrangements address different interference paths.

Shielding Feature

Primary Purpose

Overall copper braid

Helps reduce external electromagnetic interference

Individual pair foil shielding

Helps reduce interference coupling between separate signal pairs

Combined pair and overall shielding

Provides both pair-level separation and overall shielding

For example, a measuring device may transmit several low-level analog signals through one cable.

When interference between measurement channels affects the receiving equipment, individually shielded pairs may be considered.

PE insulation may also offer useful electrical characteristics for applications where capacitance is important.

However, actual capacitance, attenuation, and frequency performance depend on the complete cable design and must be checked against its datasheet.

Can Li2YCY-PiMF Replace an Existing PROFIBUS Cable?

Not automatically.

PiMF describes a shielding arrangement, not a complete industrial communication specification.

For PROFIBUS applications, the cable must satisfy the requirements of the particular communication system.

These may include:

  • Characteristic impedance

  • Capacitance

  • Attenuation

  • Conductor configuration

  • Transmission speed and cable length

  • Connector and termination compatibility

The PROFIBUS Interconnection Technology Guideline provides reference requirements for PROFIBUS cable and interconnection systems.

A replacement should therefore be evaluated against the original cable datasheet and the connected equipment's communication requirements.

Cable Comparison by Signal Type and Wiring Conditions

The following table summarizes the main structural differences and typical applications.

Cable Model

Typical Construction

Applications to Evaluate

LiYY

PVC insulation and sheath; no metallic shield

Short control circuits and low-interference cabinet wiring

LiYCY

PVC insulation and sheath; overall copper braid

General shielded equipment control and instrumentation wiring

LiYCY-TP

Twisted pairs with overall copper braid

Multiple analog signals, sensors, and compatible differential signal circuits

Li2YCY-PiMF

PE insulation; individual pair foil shields and overall copper braid

Sensitive multipair measurement and data circuits requiring specific electrical characteristics

The table is a starting point for engineering evaluation rather than a substitute for model-specific specifications.

Where the installation includes repeated movement, additional mechanical requirements apply regardless of shielding construction.

What Changes When Signal Cables Enter a Drag Chain?

A flexible cable is not necessarily suitable for continuous drag-chain operation.

A cable may bend easily during installation but still experience premature damage when subjected to repeated reciprocating movement.

Inside a cable carrier, conductors, insulation, shielding, core assembly, and outer sheath must all accommodate the movement.

Dynamic Parameters That Matter

For moving applications, equipment designers should check:

  • Minimum dynamic bending radius

  • Cable carrier travel length

  • Operating speed

  • Acceleration and deceleration

  • Expected movement cycles

  • Installation space and cable diameter

  • Strain relief and cable routing

  • Torsional movement, where applicable

For robotic joints, the required torsion angle and repeated twisting conditions should also be evaluated.

A PUR outer sheath may provide useful mechanical and environmental properties, but the sheath material alone does not establish continuous-flex suitability.

The complete cable construction must be designed for the actual dynamic application.

When sourcing European-style flexible signal cables, industrial buyers may need corresponding constructions from a different manufacturer.

RONA Cable provides a range of industrial flexible cable models associated with common LiY-family designations.

The following cross-reference is based on RONA's product model information.

RONA Equivalent Cable Models for LiYY, LiYCY, LiYCY-TP and Li2YCY-PiMF European Signal Cables

Reference Cable Model

RONA Corresponding Model

LiYCY

Rona-GFVP

LiYY (TP)

Rona-GFV

LiYCY (TP)

Rona-LFVSP

Li2YCY (TP)

Rona-LFVSP

Li2YCY (TP) fine-wire

Rona-LFVSP

Li2YCYv (TP)

Rona-LFVSP

LiHH

Rona-LFU

LiHCH

Rona-LFUP

LiHCH (TP)

Rona-LFUSP

Li2YCY PiMF

Rona-HFVSPP

These model correspondences provide a reference for identifying possible RONA cable options.

They do not mean that every listed construction is electrically or mechanically identical to the corresponding European-style model.

For example, Rona-LFVSP appears against several reference designations. The exact conductor arrangement, insulation, shielding structure, rated voltage, and dimensions must therefore be reviewed for the required version.

Similarly, the Rona-HFVSPP construction should be checked against the electrical and shielding requirements of the original Li2YCY-PiMF cable.

For a broader introduction to these European-style designations, see RONA's VDE LiY flexible signal cable guide.

What to Check Before Replacing an Existing Signal Cable

When equipment manufacturers request an alternative cable, the original model name is only the starting point.

The replacement must be compatible with the equipment and its installation conditions.

Electrical and Signal Requirements

Confirm the signal type, number of cores or pairs, conductor size, rated voltage, and required electrical characteristics.

For communication circuits, include the protocol, impedance, capacitance, and maximum cable length requirements.

Shielding and Termination

Identify whether the existing cable uses no shield, an overall braided shield, individually shielded pairs, or a combined shielding structure.

Shield connections must also be compatible with the equipment design.

Physical Dimensions and Connectors

A replacement cable may have suitable electrical characteristics but still be incompatible with the existing connector or cable gland.

Confirm the cable outside diameter, core arrangement, shield termination space, and installation geometry.

Environmental and Mechanical Conditions

Check whether the cable will remain fixed or experience occasional movement, repeated bending, or torsion.

Temperature range, oil exposure, abrasion, jacket material, and bending radius should also be reviewed.

For additional industrial cable categories, explore RONA's industrial flexible cable products.

Frequently Asked Questions

What Is the Main Difference Between LiYY and LiYCY Cable?

LiYY is generally an unshielded PVC flexible multicore cable, while LiYCY includes an overall copper braided shield. LiYCY may be considered where external electrical interference is a concern.

Is LiYCY-TP Better Than Standard LiYCY for Encoder Signals?

LiYCY-TP provides twisted pairs that can support appropriate differential signal arrangements. However, actual encoder compatibility depends on the device's electrical and transmission requirements.

Does Li2YCY-PiMF Always Provide Better Signal Performance?

Not necessarily. Individual pair shielding and overall shielding can help address specific interference problems, but the actual result depends on the circuit, installation, grounding, and cable electrical characteristics.

Can Standard LiYCY Cable Be Used in a Drag Chain?

Only when the particular cable construction is rated for the required dynamic conditions. General cable flexibility does not confirm continuous drag-chain suitability.

Can RONA Provide Alternatives for Existing European Signal Cable Models?

RONA provides corresponding cable series for several LiY-family models. Final suitability depends on the required electrical, mechanical, and dimensional specifications.

Send Your Cable Model or Drawing to RONA

Looking for an alternative to LiYY, LiYCY, LiYCY-TP, Li2YCY-PiMF, or another industrial signal cable?

RONA Cable can help review your existing cable model and discuss suitable construction options for your equipment.

You can share the original cable designation, sheath marking, technical datasheet, drawings, conductor configuration, signal type, cable length, and installation conditions.

For communication cables, include the equipment protocol or controller model. For drag-chain or robotic applications, provide the movement parameters and available installation space.

Even a photo showing the existing cable marking can be a useful starting point for identifying the required specifications.

Contact RONA Cable to discuss an alternative signal cable or customized construction.

RONA is a premier high-tech company specializing in the research, design, and production of special flexible cables. We provide reliable connectivity solutions through professional engineering technology and rigorous manufacturing standards.

Quick Links

Main Product Category

Contact Us

Tel: +86-21-5771-5338
WeChat/WhatsApp: +8613961635976
Office address: No.668 Xinzhuan Road,Songjiang District, Shanghai, China.
Copyright © 2026 Shanghai RONA Cable Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy  沪ICP备2025153993号-1